繁體版 English
登录 注册

回水温度的英文

发音:  
"回水温度"怎么读用"回水温度"造句

英文翻译手机手机版

  • return water temperataure
  • return water temperature

例句与用法

  • Temperature difference between supply and return water
    水系统供水温度与回水温度之差
  • The fitting can be mounted as a shut - off valve or a shut - off valve for a particular floor in a
    还有一个新产品是multibox c rtl型多功能温控盒,带有密封盖和内置回水温度限制器。
  • Presents two common heat recovery methods for water cooling chillers . recommends the control scheme by monitoring the return water temperature . presents two design schemes for chilled water systems
    摘要介绍了两种常见的水冷冷水机组热回收方式。推荐采用热水回水温度控制方案。介绍了冷水系统的两种设计方案。
  • We can make sure the temperature of the second - net water isupplied and watcr - returned in the most cold and hot times including our experience , get the temperature change curve of the waer - supp1ied in the first - nct and the second - net with the change of temperatllre outdoor
    根据实际运行经验可以确定最冷时和最暖时的二次供水和回水温度参数,得出热网最大输送能力时的一次热网和二次热网供水温度随室外温度变化曲线。
  • The smaller the the difference of the temperature of feedwater and backwater is , the more evenly and slowly the temperature distribution is . the smaller the thickness of overburden layer and the distance of two tubes are , the more evenly and slowly the temperature distribution is
    在供回水温度和覆盖层厚度均不变的条件下,排管间距越小,其温度分布越为平缓,地板表面的温度分布也越为均匀,地板表面平均温度也越高。
  • The paper analyzes the non - lineal relations of the quantity of heat exchange and water flux of coil exchanger in part - load operating condition , the shortage of deciding the water flux in bypass pipe , the disadvantage that the operating condition of pumps and chiller ca n ' t be met with the load change of the air conditioning system in different operating condition of using pressure - difference bypassing control in primary water pump system . using load control method in the change of the operating condition of primary water pump system can realize that the load change is small and reasonable in the on / off condition of pumps and m m chiller by comparing load control method in primary variable - flow water pump system with pressure - difference bypassing control method , back water temperature control method
    本论文从目前空调工程中使用的变流量水系统入手,研究了盘管换热器在部分负荷下水流量与换热量的非线性关系,分析了文献中介绍的旁通管通流能力选择的不足之处和一次泵水系统采用压差旁通控制时,工况转换不能满足系统控制要求的缺陷;比较了一次泵变流量水系统中压差旁通控制法、回水温度控制法、负荷控制法的精确性,并得出了在一次泵水系统的工况转换时,采用负荷控制法能使冷水机组及其相应水泵在启停时的负荷变化范围较小,更符合建筑物的冷量需求,节能效果较好的结论。
  • The hvac system did not work well in yifu library of beijing university of technology , so we have a local investigation . finally we found out the reason for “ cold in winter and hot in summer ” . in may eighth , we tested the temperature of reading room 、 office ; supply and return water temperature ; water flow and the velocity of fan coil units . we simulate the library with energyplus , which is developed by u . s . a , compared the simulation results with the true temperature and they anastomosed well . on the basis of good simulation results , we simulate the hot day in summer and the cold day in witer and get the temperature of the reading room and the office
    于空调系统开启的条件下测试了馆内各功能房间的温度;供、回水温度及流量;风机盘管的出风速度。又运用美国新一代能耗分析软件energyplus对当日馆内的温度进行模拟,将模拟值与实测值进行比较,验证两者基本吻合。进一步模拟出夏季与冬季设计日图书馆内各功能房间的室内温度,作为分析依据。
  • Abstract : a thermo - economical diagnostic mathematical model for pressurizedwater reactor ( pwr ) nuclear cogeneration plant is proposed based on heat assignment method . this model simplifies the calculation of thermal system and can be used to calculate the index variations caused by heating steam parameters as temperature , return percentage and return place of the return water . some examples are given to show the usefulness of this model
    文摘:基于热电联产机组热量法分配的特点,建立了热电联产压水堆机组热力系统发生变化对热经济性指标影响的计算模型,提出了供热系统参数? ?供热回水率、回水温度、回水地点变化对压水堆机组热经济性影响的定量诊断数学模型,可将复杂的热力系统全面计算简化成3个一次方程.通过实例计算,验证了所提数学模型是正确可行的,同时具有概念清晰、计算简捷的特点
  • To make the thermal efficiency best , y , a , av / as should be : r : [ 60 - 75 ] a : [ 1 - 1 . 5 ] av / as : [ 0 . 8 - 1 ] in this paper , numerical model of solar radiant floor heating system is also built . the model of numerical model is solved by finite differance method . the smaller the distance to the tube is , the higher the temperature on the surface of the floor is
    地板表面相邻两管间水平方向的温度分布:距离加热管越近,温度越高;两管中间处温度最低;供回水温差越小,地板表面温度分布越平缓;在供回水温度和排管间距均一定的情况下,地板覆盖层厚度越大,其温度分布越为平缓,对应的地板表面温度分布越均匀。
用"回水温度"造句  
回水温度的英文翻译,回水温度英文怎么说,怎么用英语翻译回水温度,回水温度的英文意思,回水溫度的英文回水温度 meaning in English回水溫度的英文回水温度怎么读,发音,例句,用法和解释由查查在线词典提供,版权所有违者必究。